BRHHH - KAPTON POLYIMIDE FILM COATED TYPE HRN616ES

Product Identification

Product ID:KAPTON POLYIMIDE FILM COATED TYPE HRN616ES
MSDS Date:08/16/1990
FSC:6750
NIIN:00N038339
MSDS Number: BRHHH

Responsible Party
E I DU PONT DE NEMOURS & CO INC
1007 MARKET ST
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515; 302-774-1000

Preparer: C.B. STOUFFER

Cage: B0589

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

POLYIMIDE FILM

CAS: 25038-81-7


TETRAFLUOROETHYLENE-ETHYLENE COPOLYMER; (POLYFLUOROCARBON

CAS: 25038-71-5


ACETAMIDE, N,N-DIMETHYL-;(DIMETHYL ACETAMIDE)

CAS: 127-19-5

RTECS: AB7700000

Fraction By Weight: 1%

OSHA PEL 10 PPM, S

ACGIH TLV: 10 PPM, S

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:NOT A PROBABLE ROUTE OF
EXPOSURE. SKIN:NO IRRIT EXPECTED. LESS THAN 1 PPM DIMETHYL
ACETAMIDE WAS EXTRACTED FROM FILM BY DISTILLED WATER AT 40C FOR 4
HRS. EYE:NOT A PROBABLE ROUTE OF EXPOSURE. M ECHANICAL IRRITATION.
INHAL:VAPORS AND FUME LIBERATED ABOVE 260C OR FROM SMOKING
TOBACCO/CIGARETTES (EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CONTAM W/COATED TYPES OF KAPTON FILM
MAY CAUSE INFLUENZA TYPE SYMPS (POLYMER FUME FEVER) W/CHILLS, FEVER
& SORE THROAT, WHICH MAY NOT OCCUR UNTIL SEVERAL HRS AFTER EXPOS&
POSS WITHIN 36-48 HR S, EVEN W/OUT TREATMENT. INHAL IS NOT
APROBABLE ROUTE OF EXPOS FOR FILM. FOR POLYMER FROM WHICH THIS FILM
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE KNOWN

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:IF EXPOSED TO FUMES FROM
OVERHEATING OR COMBUSTION, MOVE TO FRESH AIR. CONSULT A PHYSICIAN
IF SYMPTOMS PERSIST. SKIN:FOR PROLONGED SKIN CONTACT, WASH WITH
SOAP AND WATER. IN CASE OF SKIN IRRITATION,CONSULT A PHYSICIAN.
EYES:FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. CONSULT A
PHYSICIAN IF SYMPTOMS PERSIST.

Fire Fighting

Extinguishing Media:WATER, CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .WEAR NEOPRENE GLOVES WHEN HANDLING REFUSE
FROM A FIRE INVOLVING FLUOROCARBON RESINS.
Unusual Fire/Explosion Hazard:CHARS BUT DOES NOT BURN. STATIC CHARGE
MAY BUILD UP DURING HANDLING OF KAPTON FILM.

Accidental Release

Spill Release Procedures:SWEEP UP TO AVOID SLIPPING HAZARD.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AWAY FROM FLAMMABLE MATERIALS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:WEAR NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . NOT REQUIRED FOR NORMAL PROCESSING.
Ventilation:LOCAL EXHAUST FOR OPERATION ABOVE 200C.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD:MAJOR OFF-GASES ARE CARBON MONOXIDE AND CARBON DIOXIDE.
EFTS OF OVEREXPOS:IS MADE, DU PONT REC TREATING POLYMER DUST AS A
NUISANCE PARTICULATE, AND HAS ESTABLISHED AN AEL OF 10 MG/M3 T OTAL
DUST, THE SAME AS TLV FOR NUISANCEPARTICULATES. CHRONIC:NONE KNOWN.

Chemical Properties

Spec Gravity:>14
Solubility in Water:INSOLUBLE
Appearance and Odor:TRANSPARENT FILM, LIGHT AMBER COLOR WITH NO ODOR.
Percent Volatiles by Volume:1 MAX

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI METAL AND INTERHALOGEN COMPOUNDS.
Stability Condition to Avoid:TEMPS >260C W/OUT ADEQ VENT. COATED TYPES
OF KAPTON WILL BURN IN AN ATMOSPHERE OF 95% OXYGEN.
Hazardous Decomposition Products:ABOVE 260C COATED TYPES OF KAPTON CAN
EVOLVE TOX GASEOUS MATLS SUCH AS HYDROGEN FLUORIDE &
PERFLUOROOLEFINS. (SUPDAT)

Disposal

Waste Disposal Methods:LANDFILL OR INCINERATE IN COMPLIANCE WITH LOCAL,
STATE AND FEDERAL REGULATIONS. INCINERATOR SHOULD BE EQUIPPED WITH
SCRUBBER TO REMOVE ACIDIC HYDROGEN FLUORIDE FROM OFF-GASES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.